User Manual

ELK17J1280, Mouse Eukaryotic Translation Initiation Factor 5 (EIF5)

| --- | --- | --- | --- |
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
Mouse EIF5 ELISA Kit instruction
Intended use
This EIF5 ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures.The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of EIF5 in the sample, this EIF5 ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus EIF5 concentration. The concentration of EIF5 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Sample collection and storages
Serum - Use a serum separator tube and allow samples to clot for 30 minutes before centrifugation for 10 minutes at approximately 3000×g. Remove serum and assay immediately or aliquot and store samples at -20℃or -80℃.Avoid repeated freeze-thaw cycles.
Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 30 minutes at 3000×g at 2-8℃within 30 minutes of collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
Note: The samples shoule be centrifugated dequately and no hemolysis or granule was allowed.
Materials required but not supplied

  1. Standard microplate reader(450nm).
  2. Precision pipettes and Disposable pipette tips.
  3. 37 ℃incubator.
    Precautions
    Name 96 determinations 48 determinations
    Microelisa stripplate 8\\*12strips 8\\*6strips
    Standard 0.3ml\\*6tubes 0.3ml\\*6tubes
    Sample Diluent 6.0ml 3.0ml
    HRP-Conjugate reagent 10.0ml 5.0ml
    20X Wash solution 25ml 15ml
    Chromogen Solution A 6.0ml 3.0ml
    Chromogen Solution B 6.0ml 3.0ml
    Stop Solution 6.0ml 3.0ml
    Closure plate membrane 2 2
    User manual 1 1
    Storage: 2-8℃. Validity:six months.