MEBEP TECH(HK) Co., Limited
Email: sales@mebep.com Website: http://www.mebep.com
Tel: +86-755-86134126 WhatsApp/Facebook/Twitter: +86-189-22896756
User Manual
ELK02J0722, Rat Creatine Phosphokinase (CPK)
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
Rat CPK ELISA Kit instruction
Intended use
This CPK ELISA kit is intended Laboratory for Research use only and is
not for use in diagnostic or therapeutic procedures.The Stop Solution
changes the color from blue to yellow and the intensity of the color is
measured at 450 nm using a spectrophotometer. In order to measure the
concentration of CPK in the sample, this CPK ELISA Kit includes a set of
calibration standards. The calibration standards are assayed at the same
time as the samples and allow the operator to produce a standard curve
of Optical Density versus CPK concentration. The concentration of CPK in
the samples is then determined by comparing the O.D. of the samples to
the standard curve.
Sample collection and storages
Serum - Use a serum separator tube and allow samples to clot for 30
minutes before centrifugation for 10 minutes at approximately 3000×g.
Remove serum and assay immediately or aliquot and store samples at
-20℃or -80℃.Avoid repeated freeze-thaw cycles.
Plasma - Collect plasma using EDTA or heparin as an anticoagulant.
Centrifuge samples for 30 minutes at 3000×g at 2-8℃within 30 minutes of
collection. Store samples at -20℃or -80℃. Avoid repeated freeze-thaw
cycles.
Cell culture supernates and other biological fluids - Remove
particulates by centrifugation and assay immediately or aliquot and
store samples at -20℃or -80℃. Avoid repeated freeze-thaw cycles.
Note: The samples shoule be centrifugated dequately and no hemolysis or
granule was allowed.
Materials required but not supplied
- Standard microplate reader(450nm).
- Precision pipettes and Disposable pipette tips.
- 37 ℃incubator.
Precautions
- Do not substitute reagents from one kit to another. Standard,
conjugate and microplates are matched for optimal performance. Use only
the reagents supplied by manufacturer.
- Do not remove microplate from the storage bag until needed. Unused
strips should be stored at 2-8°C in their pouch with the desiccant
provided.
- Mix all reagents before using.
Remove all kit reagents from refrigerator and allow them to reach room
temperature ( 20-25°C).
Materials supplied
Name 96 determinations 48 determinations
Microelisa stripplate 8*12strips 8*6strips
Standard 0.3ml*6tubes 0.3ml*6tubes
Sample Diluent 6.0ml 3.0ml
HRP-Conjugate reagent 10.0ml 5.0ml
20X Wash solution 25ml 15ml
Chromogen Solution A 6.0ml 3.0ml
Chromogen Solution B 6.0ml 3.0ml
Stop Solution 6.0ml 3.0ml
Closure plate
membrane 2 2
User manual 1 1
Note: Standard (S0 →S5) concentration was followed
by:0,6.25,12.5,25,50,100 ng/mL.
Reagent preparation
20×wash solution:Dilute with Distilled or deionized water 1:20.
Assay procedure
- Prepare all reagents before starting assay procedure. It is
recommended that all Standards and Samples be added in duplicate to the
Microelisa Stripplate.
- Add standard: Set Standard wells, testing sample wells. Add standard
50μl to standard well.
- Add Sample: Add testing sample 10μl then add 40μl of Sample Diluent
to testing sample wel.
- Add 100μl of HRP-conjugate reagent to each well, cover with an
adhesive strip and incubate for 60 minutes at 37°C.
- Aspirate each well and wash, repeating the process four times for a
total of five washes. Wash by filling each well with Wash Solution
(400μl) using a squirt bottle, manifold dispenser or autowasher.
Complete removal of liquid at each step is essential to good
performance. After the last wash, remove
Storage: 2-8℃. Validity:six months.
FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS!
PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!